Cobb County Fire & Emergency Services, Training Tower Fire

Cobb County Fire & Emergency Services, Training Tower Fire

Marietta, GA

Forensic fire damage investigation and repair drawings for a 5000 SF, 4-story, cold formed and load bearing metal panel fire training facility. There was extensive damage to walls and floors, including a partial floor collapse that occurred when combustible partitions ignited during a training exercise. Project included structure analysis and construction documents requiring rebuilding with all non-combustible materials.